GFEVT500-R18高速熔斷器(10A-100A)500Vac/dc
[附件: Download]
Fuse Ratings
Part No.
|
Fuse Amps
|
Average @50KA/500Vdc
|
Power Loss (W)
|
Approvals
|
A2s Melting
|
A2t Clearing
|
80%
|
100%
|
|
GFEVT500-10A-18R
|
10A
|
7
|
13
|
2
|
3
|
○ Pending
|
GFEVT500-16A-18R
|
16A
|
7
|
51
|
7
|
9
|
○ Pending
|
GFEVT500-20A-18R
|
20A
|
32
|
231
|
6
|
7
|
○ Pending
|
GFEVT500-25A-18R
|
25A
|
32
|
263
|
6
|
7
|
○ Pending
|
GFEVT500-32A-18R
|
32A
|
34
|
316
|
7
|
9
|
○ Pending
|
GFEVT500-35A-18R
|
35A
|
35
|
345
|
7
|
9
|
○ Pending
|
GFEVT500-40A-18R
|
40A
|
108
|
460
|
7
|
9
|
○ Pending
|
GFEVT500-45A-18R
|
45A
|
114
|
518
|
9
|
11
|
○ Pending
|
GFEVT500-50A-18R
|
50A
|
126
|
690
|
9
|
11
|
○ Pending
|
GFEVT500-63A-18R
|
63A
|
149
|
900
|
10
|
12
|
○ Pending
|
GFEVT500-70A-18R
|
70A
|
231
|
1140
|
14
|
18
|
○ Pending
|
GFEVT500-80A-18R
|
80A
|
275
|
1800
|
16
|
20
|
○ Pending
|
GFEVT500-90A-18R
|
90A
|
418
|
2520
|
16
|
20
|
○ Pending
|
GFEVT500-100A-18R
|
100A
|
517
|
3360
|
19
|
24
|
○ Pending
|
-
DC Cold Resistance are measured at <10% of rated current in ambient temperature of 25℃;